Type: Load Cell
Use: Force Measurement
Theory: Convert Force Into Electrical Signal
Output: MV/V
Description: SC601 Load Cell
Item: SC601
Material: Aluminum Alloy
Comprehensive Error: ±0.02%
Excitation Voltage: 9~12 VDC
Accuracy Class: 0.03%F.S / 0.02%F.S
Rated Output: 2.0±0.15mV/V
Sensitivity:: 0.0016 %RO/℃
Safe Over Load: 150% RO
IP Grade: IP65
Application: Electronic Scale, Table Top Scale, Pricing Scale, Fore Test Equipment
Port: Shenzhen, Hongkong, Any Port Of China
Basic Infomation
Place of Origin: Guangdong, China
Brand Name: SNC
Model Number: SC601
Payment & Shipping Terms
Packaging Details: planar beam load cell 10kg for bench scales----10 units per box
Supply Ability: 10000 Piece/Pieces per Month planar beam load cell 10kg for bench scales
Product Description

Czl 601 Gpb100 Beehive Scale 60 Kg 120 Kg Load Cell

Product Description

 

 Features: 

1, aluminum alloy, hermetically sealed with glue to IP65,

2, Surface anodized and anti-corrosion, integral structure and easy installation.

3, Application:  electronic top scale, floor scale and other weighing equipment.
It uses 4-core shielded cable (φ4×420mm). The length of the cable is adjustable according to customer requirement.

 

Parameters: 

Application Price computing scale, table top scale
Model SC601
Capacity 3kg, 5kg, 6kg, 10kg, 15kg, 20kg, 30kg, 40kg, 50kg, 60kg, 100kg, 120Kg
rated output 2.0±0.15mV/V
Accuracy class 0.03%F.S / 0.02% F.S
maximum number of verification intervals 2000Nmax
Minimum loadcell cerification intervals Emax/5000 Vmin
Combined error ≤±0.03% RO
Creep 0.003%RO/30min
Temp. effect on sensitivity 0.0016 %RO/℃
Temp.effect on zero 0.003%RO/℃
Zero balance ±1.0 %RO
Input resistance 402±6 ohm
Output resistance 350±3 ohm
insulation resistance 5000 MΩ(50V)
Recommended excitation voltage 10-15V
Compensated temperature range -10-+40℃
operating temperature range  -35-+80 ℃
safe overload 150 %RO
Ultimate overload 200%RO
loadcell material Auuminum
platform size 250x350 mm
Connecting cable  Φ4.2x350 mm
Method of connecting wire Red- input+, black- Input-. Green- Output+, White- output -
 60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 0
 
 
Accessories

60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 1 

Application:
60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 2
Related Products
60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 3

 

Production Process

60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 4

Company Information

Sensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test.

 

Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users.

60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 5

60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 6

 

Packaging & Shipping

60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 7 

FAQ

1.How to place an order ?
Please provide us more details of what you want, such as: application, measurement range, output, accuracy, thread type, electric connector and other related parameters.

 

2.Does SNCoffer any discount ?
Yes, if you buy large QTY, please contact us, we will give you a big discount.

 

3.What terms of payment are available ?
We accept T/T, L/C, Trade assurance, Western Union, Paypal, etc.

 

4.When will you arrange the production ?
We will arrange the production immediately after receiving your payment.

 

5.How do you ensure good product quality ?
We have a complete quality control system, all of our products are fully checked by IQC, OQC departments

before shipping to our clients.

 

6.Do you have warranty ?
Yes, we provide 1 year warranty for most of our products. Some products we offer 15month to 24 months warranty.

Contact Us

 60 Kg 120 Kg Load Cell Czl 601 Gpb100 Beehive Scale Theory Convert force into electrical signal Sensitivity 0.0016 %RO/C 8

Czl 601 Gpb100 Beehive Scale 60 Kg 120 Kg Load Cell

Czl 601 Gpb100 Beehive Scale 60 Kg 120 Kg Load Cell

Czl 601 Gpb100 Beehive Scale 60 Kg 120 Kg Load Cell

Recommended Products
Get in touch with us
Contact Person : Jason Zhu
Tel : +86 13282015399
Characters Remaining(20/3000)